![GB50526-2010公共广播系统工程技术规范(英文版)](https://wfqqreader-1252317822.image.myqcloud.com/cover/896/33688896/b_33688896.jpg)
3.3 Electro-acoustic Performance Indexes
3.3.1 The electro-acoustic performance indexes of PAS in every service zone shall be in accordance with those specified in Table 3.3.1.
Table 3.3.1 Electro-acoustic performance indexes of PAS
![img](https://epubservercos.yuewen.com/7E2126/18000635808208506/epubprivate/OEBPS/Images/txt003_4.jpg?sign=1739317905-QsgrHQNK3caOtW394k7mZJAPHGkAPF8n-0-cfe2f652e6293b68081ab3ef78a721dd)
*:The ENSPL of emergency broadcast shall meet the requirements stipulated in item 2,article 3.2.5 of this code.
![img](https://epubservercos.yuewen.com/7E2126/18000635808208506/epubprivate/OEBPS/Images/txt003_5.jpg?sign=1739317905-VX9s2N8FSe2aRDHJNtnKOjlqt8d1BVDm-0-ee1a0ad256a70e381c581528851ead8c)
Figure 3.3.1-1 Tolerance domain of indoor transmission frequency response of business announcement class 1/background broadcast class 1
(the maximum value of the measured curve is set to be 0dB)
![img](https://epubservercos.yuewen.com/7E2126/18000635808208506/epubprivate/OEBPS/Images/txt003_6.jpg?sign=1739317905-WyGS8cgVMc9B7cYvIiOmxiIvma5qjrcP-0-77f1a5a1cbaa6d95a7da38546bef4e5a)
Figure 3.3.1-2 Tolerance domain of indoor transmission frequency response of business announcement class 2/background broadcast class 2
(the maximum value of the measured curve is set to be 0dB)
![img](https://epubservercos.yuewen.com/7E2126/18000635808208506/epubprivate/OEBPS/Images/txt003_7.jpg?sign=1739317905-Aw844mhrDhkNOYdQ90hEN9aLv9mJdaUU-0-ce48d0708c4af4fa5f75fed4d8da53d3)
Figure 3.3.1-3 Tolerance domain of indoor transmission frequency response of business announcement class 3
(the maximum value of the measured curve is set to be 0dB)
3.3.2 For indoor PAS,the relevant architectural acoustic characteristics should comply with the requirements of current national standards GB/T 50356,Code for architectural acoustical design of theater,cinema,and multi-use auditorium and JGJ/T 131,Specification for acoustical design and measurement of gymnasium and stadium.